Dew Point Monitor – P Series

USD $2,040USD $3,230

Portable dew point meter with touch screen display and data logging. Measure pressure dew point (PDP), relative humidity, temperature and pressure (if using the optional integrated pressure sensor).

Pressure Dew Point (PDP) Range
-60°C to +60°C (-76°F to +140°F)
-80°C to +20°C (-112°F to +68°C)
-110°C to +0°C (-166°F to +32°F)

Gas Pressure Range
up to 17 bar (247 psi)

Accuracy
Dew point measurements: ±2%
Temperature measurements: ±0.5 °C
Pressure @ 23°C (optional): ±0.3% FS

Display
LCD Touch screen

Data Logging
Yes (requires USB stick and power)

Power Requirement
Standard wall socket, 220vAC

Application
Manufacturing and industrial use
Temporary or permanent installation
Refrigerant, desiccant, drum or membrane dryers

United States dollar ($) - USD
  • Australian dollar ($) - AUD
  • United States dollar ($) - USD
  • Euro (€) - EUR
  • Canadian dollar ($) - CAD
  • Pound sterling (£) - GBP
  • Singapore dollar ($) - SGD
SKU: DEP Categories: , Tag:

This portable dew point meter is suitable for refrigerant, desiccant, drum and membrane dryers. The sensor design provides long-term, reliable, high-accuracy measurements.

The Dew Point meter is available with an in-built display and data logging. For data logging, you need to leave the portable unit powered on with a USB inserted into the display panel. 

Best suited to

  • Where a temporary meter is required
  • Refrigerant, membrane, desiccant or drum dryers
  • Indoor applications

Key features of the Wall Mount Dew Point Monitor

  • Ultra fast response time
  • Accuracy up to +/- 2°C
  • Suitable for refrigerant, membrane, desiccant or drum dryers 
  • Dew Point Measurement Range options:
    • -60°C to +60°C (-76°F to +140°F)
    • -80°C to +20°C (-112°F to +68°C)
    • -110°C to +0°C (-166°F to +32°F)
  • Excellent long term stability
  • Anti-condensation, anti-particulate pollution, oil vapour and most chemicals
  • Optional integrated pressure transducer 
  • High resistance to electrical disturbances

Important

  • A minimum flow rate of > 1 L/min is required for the sensor to read accurately
  • Incorrect use can damage the sensor and void the warranty. If you aren’t sure how to use the sensor, please contact us. Full instructions are available in the User Manual.

Portable Dew Point Meter comes with

  • 1.5 meter power cable with USA, EURO, UK or Australian power plug
  • 6 mm PTFE tube with nitto fitting. Tube length: 1.5 meters (5 foot) long
  • Calibration certificate
  • User Manual
  • 12 month warranty

Options for the Portable Dew Point Meter

  • Integrated pressure sensor
  • Dew Point ranges:
    • -60°C to +60°C (-76°F to +140°F) or
    • -80°C to +20°C  (-112°F to +68°F) or
    • -110°C to +0°C (-166°F to +32°F)
  • 1.5 meter power cable suitable for USA, EURO, UK or Australian power sockets
  • Gas Types: Air, Argon, Carbon Dioxide, Carbon Monoxide, Helium, Hydrogen, Nitrogen, Oxygen

Warranty

12 month warranty

Technical Documents

User Manual

Product Flyer

Other information

Part Numbers

  • -60°C to +60°C (-76°F to +140°F) Dew Point Range: DEP011001, DEP012001, DEP013001, DEP014001, DEP015001, DEP111001, DEP112001, DEP113001, DEP114001, DEP115001
  • -80°C to +20°C (-112°F to +68°F) Dew Point Range: DEP021001, DEP022001, DEP023001, DEP024001, DEP025001, DEP121001, DEP122001, DEP123001, DEP124001, DEP125001
  • -110°C to +0°C (-166°F to +32°F) Dew Point Range: DEP031001, DEP032001, DEP033001, DEP034001, DEP035001, DEP131001, DEP132001, DEP133001, DEP134001, DEP135001

Please refer to our Terms and Conditions of Sale.

Weight N/A
Dimensions N/A

Specifications

General

Technology

Polymer sensor for dew points between -60°C to +60°C (-76°F to +140°F)

Alumin-Oxide sensor for dew points between -80°C to +20°C  (-112°F to +68°F)

Quartz sensor for dew points between -110°C to +0°C (-166°F to +32°F)

Dryer Types

Compressed air and gas systems up to 4 MPa (600 PSI)

  • Desiccant dryers
  • Membrane dryers
  • Drum dryers
  • Refrigerant dryers 

Gases

Air, Argon, Carbon Dioxide, Carbon Monoxide, Helium, Hydrogen, Nitrogen, Oxygen

Accuracy

Dew Point: 

  • +60 to -60°C: ±2%
  • -60 to -110°C: ±3%

Temperature: ±0.5°C

Pressure: ±0.3% full scale (at 23°C), ±0.01 bar/10°C

Note: the accuracy of the sensor is affected by on-site conditions. Contaminants such as oil, moisture, particles or other impurities can affect the calibration and accuracy of the sensor.

Minimum Gas Flow Required

> 1 litre per minute

Measurement Ranges

Dew Point Measurement Range

  • -60°C to +60°C  |  -76°F to 140°F

or

  • -80°C to +20°C  |  -112°F to +68°C

or

  • -110°C to +0°C  | -166°F to +32°F

Pressure Measurement Range

  • 0 to 17 bar
  • 0 to 247 psi

Gas Temperature Measurement Range

  • -40°C to +100°C
  • -40°F to +212°F

Other

Power Supply

Standard wall socket, 220vAC

Electrical Connection

1.5 meter power cable with plug socket

Plug Socket

Choice of plug socket: No plug, USA, Euro, UK, Australia

Display

7″ LCD Touch screen

Data Logging

Yes

Data Recording

Max 16G USB Flash Disk

Mechanical Connection

6 mm stainless steel quick connector

Ambient Temperature Range

  • 0°C to +50°C
  • 32°F to +122°F

Relative Humidity

0 to 95 % RH

Dimensions

  • 346 mm wide x 103 mm tall x 220 mm deep
  • 13.6” wide x 4.1” tall x 8.7″ deep

Electromagnetic Compatibility

According to IEC 61326-1

Installation Type

Permanent installation, or
Temporary installation

Calibration Frequency

  • Every 2 years (provided the sensor is not exposed to relative humidity above 85%).
  • Annual calibration is required if the sensor is exposed to relative humidity above 85%.

Warranty Period

12 months

Downloads

User Manual

Product Flyer

 

Portable Dew Point Sensor - User Manual Flyer - Dew Point - Portable Series