Menu Close

ATEx Inline Flow Meter – IP67

Price range: USD $1,821 through USD $4,143

ATEX rated thermal mass flow meter suitable for clean, dry gas. Ideal for harsh environments or outdoor installations. Measure flow, mass flow, consumption and gas temperature.

Flow Range: 0.1 to 250 Nm/s (0.3 to 820 ft/sec)

IP Rating: IP67

ATEx Rating: Optional

Pipe Sizes: DN15 to DN80

Accuracy: ±1.5% reading, ±0.3% full scale

Output: Modbus (RS485) and 4-20mA

Power Requirement: 18 to 30VDC / 5W@24VDC

Applications
• Outdoors or harsh environments
• Clean and dry compressed air and inert gases
• Manufacturing, industrial and pharmaceutical use
• Temporary or permanent installation

United States dollar ($) - USD
  • Australian dollar ($) - AUD
  • United States dollar ($) - USD
  • Euro (€) - EUR
  • Canadian dollar ($) - CAD
  • Pound sterling (£) - GBP
  • Singapore dollar ($) - SGD

Applications

Outdoor thermal mass flow meters are perfectly suited for measuring clean, dry compressed air and inert gases, where accuracy on smaller pipe sizing is important.

Typical applications include:

  • Clean, dry compressed air and inert gases
  • Process gases
  • Clean rooms
  • Manufacturing, industrial and pharmaceutical industries
  • Outdoor / harsh environments
  • Explosive environments (ATEx rated)
  • Vacuums
  • Small pipes < DN80
  • Low flow
  • Permanent installation

Important

  • The sensor must be installed (i) in dry gas, (ii) at 90° to the pipe and (iii) away from bends, edges, seams, changes in pipe size and other obstructions,
  • Incorrect wiring or installation can give false readings, damage the sensor and void the warranty. If you aren’t sure how to install or wire the sensor, please contact us. Full installation and wiring instructions are available in the User Manual.

ATEx Inline Flow Meter Pack

  • Flow meter with flange connection
  • M12 connector
  • Traceable calibration certificate
  • User Manual
  • 12 month warranty

ATEx Inline Flow Meter Options

  • Pressure: 1.6 MPa (16 bar) or 4.0 MPa (40 bar)
  • Pipe Section: DN15, DN20, DN25, DN32, DN40, DN50, DN65 or DN80
  • Gas Types: Air, Argon, Carbon Dioxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen
  • Display Languages: English, French, German, Italian, Portuguese, South Korean, Spanish, Turkish
  • Units of Measure:
    • Flow: m3/h, m3/min, m3/s, l/min, l/s, cfm, kg/h, kg/min, kg/s
    • Velocity: m/s, ft/s
    • Consumption: m3, ft3, kg
    • Temperature: °C, °F

Warranty & Calibration

12 month warranty

Calibration is recommended every 2 years (provided the sensor is not exposed to relative humidity above 85%).
Annual calibration is required if the sensor is exposed to relative humidity above 85%.

Accessories

Accessories such as mechanical and electrical fittings are available on the Accessories page.

Other Information

Please refer to our Terms and Conditions of Sale.

Dimensions 69 × 21 × 17 cm
ATEX Rating

No, Yes – ATEX rated

Pressure

1.6 MPa (16 bar or 232 psi), 4.0 MPa (40 bar or 580 psa)

Pipe Size

DN15, 1/2", DN20, 3/4", DN25, 1", DN32, 1.25", DN40, 1.5", DN50, 2", DN65, 2.5", DN80, 3"

Gas Flow Direction

Left to Right → → →, Right to Left ← ← ←

Gas Type

Air, Argon, Carbon Dioxide, Helium, Hydrogen, Natural Gas, Nitrogen, Nitrous Oxide, Oxygen

HS Code

902680

Features

  • Style: Inline type sensor
  • Technology: Thermal mass
  • ATEx Rating:
    • Ex II 2G Ex db IIC T6 Gb
    • Ex II 2D Ex tb IIIC T80°C Db
  • IP Rating: IP67
  • Pipe Sizes:  DN15 – DN80 provided minimum velocity is maintained
  • Minimum Flow Velocity: 0.1 Nm/s
  • Flow Range:  0.1 to 250 Nm/s
  • Gas Pressure: up to 40 bar (580 psi)
  • Gas Temperature: -40 to +150°C (-40 to +302°F)
  • Accuracy: +/-1.5% reading, +/-0.3% full scale
  • Power Requirement: 18 to 30VDC / 5W@24VDC
  • Outputs: Modbus RTU and 4 to 20 mA + Pulse outputs
  • Display: 2″ ultra-wide viewing angle LCD touch screen
  • Display Languages:
    • English
    • French
    • German
    • Italian
    • Portuguese
    • South Korean
    • Spanish
    • Turkish
  • Data Logging: No
  • Bi-directional: No
  • Measure: Standard flow, mass flow, velocity, consumption and temperature
  • Measurement Units:
    • Flow: m3/h, m3/min, m3/s, l/min, l/s, cfm, kg/h, kg/min, kg/s
    • Velocity: m/s, ft/s
    • Consumption: m3, ft3, kg
    • Temperature: °C, °F
  • Other Features:
    • Integrated temperature sensor
    • Low pressure drop
    • No moving parts, low pressure drop
    • Full electrical isolation to filter out disturbances
    • Stable signals
    • Vibration resistant
    • Ultra-wide Turndown Ratio, 1:2500
  • Warranty: 12 months

Inline v Insertion Flow Meters

Compressed Air Alliance offers two types of thermal mass flow meters – insertion flow meter and inline (or in-line) flow meter. Both flow meters (inline and insertion style) have a streamlined sensor tip which ensures minimal impact on gas flow while maintaining accuracy over a wide flow range.

Inline Flow Meters

  • Inline flow sensors include a section of pipe as part of the flow meter. You will need to turn off compressed air and cut a section of pipe out to install the inline flow meter.
  • Inline flow meters are best used for permanent installations.
  • Suitable for pipes from DN15 to DN80

Insertion flow meters

  • Insertion flow sensors are inserted into the pipe through a valve. They can be inserted under pressure so you don’t need to turn off your compressed air system during installation.
  • Insertion flow meters are best used for permanent and temporary installations.
  • Suitable for pipes from DN20 to DN300
  • For information on Insertion Flow Meters, refer to Inline Flow Meter page.

Downloads

User Manual